16.0 GHz Oscilloscopes – Oscilloscopes Solutions http://oscilloscopes.solutions Quality Refurbished Oscilloscopes Wed, 15 Feb 2017 21:30:17 +0000 en-US hourly 1 https://wordpress.org/?v=4.7.8 Tektronix DPO71604 Digital Phosphor Oscilloscope http://oscilloscopes.solutions/product/tektronix-dpo71604-digital-phosphor-oscilloscope/ Tue, 07 Feb 2017 18:08:05 +0000 http://oscilloscopes.solutions/product/tektronix-dpo71604-digital-phosphor-oscilloscope/ Signal Fidelity of Tektronix Oscilloscopes Ensures Confidence in Your Measurement Results

  • High bandwidth up to 20 GHz matched across 2, 3, or 4 channels and enabled by Tektronix proprietary DSP enhancement. The user-selectable DSP filter on each channel provides magnitude and phase correction plus bandwidth extension to 20 GHz for more accurate representation of extremely fast signals. The DSP filter on each channel can also be switched off to take advantage of true analog bandwidth for applications needed the highest available raw data capture.
  • Bandwidth Enhance to the probe tip, extended to support bandwidth steps, gives you an oscilloscope with bandwidth adjustable to capture transitions accurately without excess frequencies and noise.
  • High sample rate on all models, on all channels, to capture more signal details (transients, imperfections, fast edges)

    • 50 GS/s on all four channels for the 12.5, 16, and 20 GHz models
    • 25 GS/s on all four channels for the 4, 6, and 8 GHz models

  • Lowest jitter noise floor and vertical accuracy for very accurate measurements
  • Longest acquisition of the industry to provide more resolution and longer time sequence

    • Standard 10 M samples per channel on the DPO70000 Series and 20 M on the DSA70000 Series
    • Optional up to 100 M samples on all four channels for the 4, 6, and 8 GHz models
    • Optional up to 200 M samples on all four channels for the 12.5, 16, and 20 GHz models
    • Easily manage this deep record length, provide detailed comparison and analysis of multiple waveform segments with the MultiView Zoom™ feature. Automatically scroll through deep records visually, or create a math expression to instantly highlight differences

  • Highest-performance probing solutions with bandwidth enhanced to the probe tip for differential and single-ended voltage signals, because accurate design verification depends on high-bandwidth access to critical signals and high-fidelity signal capture
]]>
Tektronix DPO71604B http://oscilloscopes.solutions/product/tektronix-dpo71604b/ Tue, 07 Feb 2017 18:18:02 +0000 http://oscilloscopes.solutions/product/tektronix-dpo71604b/ Digital Phosphor Oscilloscope 16GHz 4-Channel 50GS/s

The DPO/DSA70000B and MSO70000 Series combine industry-leading bandwidth of 20 GHz with the industry’s highest waveform capture rate, best signal fidelity, lowest noise floor and the only available hardware-based serial pattern trigger for data rates up to 5 Gb/s. The MSO70000 also includes 16 logic channels with a very accurate 80psec timing resolution. Together, these are the most powerful real-time oscilloscopes on the market, enabling you to make the most challenging measurements with the confidence you only get from a Tektronix oscilloscope.



Features & Benefits

  • Bandwidth 16 GHz
  • Input Channels 4
  • Rise Time 10% to 90% (Typical) 24.5 ps
  • Input Coupling DC (50 ?), GND
  • Input Impedance 50 ? +/-2%, 1 M? with TCA-1MEG adapter
  • Time Base Range 10 ps/div to 1000 s/div
  • Time Resolution (in ET/IT mode) 100 fs
]]>
Tektronix DSA71604 http://oscilloscopes.solutions/product/tektronix-dsa71604/ Tue, 07 Feb 2017 18:18:17 +0000 http://oscilloscopes.solutions/product/tektronix-dsa71604/ 300,000 wfms/s Maximum per Channel… ]]> 4 Channel 16GHz Digital Serial Analyzer



Features:

16 GHz Bandwidth

Up to 50 GS/s Real-time Sample Rate

Up to 200 Megasamples Record Length with MultiView Zoom Feature for Quick Navigation

Fastest Waveform Capture Rate with >300,000 wfms/s Maximum per Channel

Digital Serial Analyzer Model with Dedicated Configuration for High Speed Serial Design and Compliance Testing

Enhanced Bandwidth to the Probe Tip Extended to Support Multiple Bandwidth Steps for Advanced Signal Integrity.

Pinpoint Triggering, with over 1400 Combinations to Address Virtually Any Triggering Situation

Unique Serial Pattern Triggering up to 3.125 Gb/s and 8b/10b Standard Protocol Triggering for Isolation of Pattern-dependent Effects

Serial Data Analysis and Compliance for PCI Express, Serial ATA, FB-DIMM, SAS, Fibre Channel, IEEE1394b, RapidIO, XAUI, HDMI, DVI, Ethernet, USB 2.0

Most Popular Jitter and Timing Measurement and Analysis Package

12.1in Largest XGA Touch Screen Display in the Industry

MyScope Custom Windows Enhance Productivity

Right-Mouse-Click Menus for Exceptional Efficiency

OpenChoice Software with Microsoft Windows XP OS Enables Built-in Networking and Extended Analysis

The DPO70000 and the DSA70000 Series are the new generation of real-time
digital phosphor oscilloscopes and are the industry’s best solution to the challenging
signal integrity issues faced by designers verifying, characterizing,
debugging and testing sophisticated electronic designs. The specialized
DSA70000 Series provides a complete and dedicated solution to address the
challenges of high-speed serial designs.

The family features exceptional performance in signal acquisition and analysis,
operational simplicity and unmatched debugging tools to accelerate your
day-to-day tasks. The largest screen in the industry and the intuitive user
interface provide easy access to the maximum amount of information.

Options:
10XL 100 MSamples/ch.

]]>
Teledyne LeCroy SDA 816Zi http://oscilloscopes.solutions/product/teledyne-lecroy-sda-816zi/ Tue, 07 Feb 2017 18:16:18 +0000 http://oscilloscopes.solutions/product/teledyne-lecroy-sda-816zi/ 16 GHz, 40 GS/s, 4ch, 20 Mpts/Ch Serial Data Analyzer with 15.3" WXGA Color Display.

A Total Solution for Serial Data Analysis

Unleash the power of serial data analysis for understanding and characterizing your design, proving compliance and understanding why a device or host fails compliance. The Quad Summary View of the SDA II software always shows the eye, TIE, bathtub curve and jitter histogram. No other Serial Data Analyzer lets you see the simultaneous interaction and real-time changes in all four views. The X-Stream II Architecture provides fast updates and the fastest eye interpretation. Combined with up to 512 Mpts record lengths and more complete jitter decomposition tools, SDA II provides the fastest and most complete understanding of why serial data fails a compliance test.

Advanced jitter decomposition methodologies and tools provide more information about root cause. Eye Doctor II Advanced Signal Integrity Tools provide more measurement precision through the use of de-embedding and emulation of cables, fixtures, emphasis, serial data channels, and receivers. All jitter decomposition analysis functions can be zoomed and time correlated to specific serial data or other events, making root cause determination faster and easier.

Automated Compliance Testing

The QualiPHY compliance test suite provides step-by-step instructions for testing compliance on a wide array of serial data standards. The process is simplified with fast, automated test operations, illustrated instructions, connection diagrams, and stop on fail feature. Complete test reporting is also provided.

SDA II – Advanced Tools to Isolate and Analyze

Flow Diagram User Interface

Eye and jitter analysis in the SDA 8 Zi begins with a simple, interactive flow diagram intuitively guides you through the setup of Eye Measurements, ­Jitter Measurements, or both at the same time.

Serial Trigger

The SDA 8 Zi Series comes standard with the 80-bit Pattern Trigger installed. The serial trigger operates up to 3.125 Gb/s and supports both 8b10b and NRZ signals, and also includes a recovered clock and data output on the front of the oscilloscope.

8b/10b Decoding

The LeCroy’s 8b/10b serial decode ­option has powerful search capabilities enabling captured waveform searches for user-defined sequences of symbols. Multi-lane analysis decodes up to four simultaneously captured lanes. User selection is provided for PCIe, PCIe 2.0, SAS, SATA, XAUI, generic 8b10b or user-defined 8b10b protocols.

Equalization

The equalization feature removes the effects created in systems that utilize equalization. Users can view the eye of a waveform as seen by a receiver that employs equalization.

ISI Plot

The ISI plot shows data-dependent ­jitter contributions to the eye pattern for the second-to-last bit of a bit length, set from 3 to 10. This plot measures data ­­­dependent jitter (DDj) eliminating the need for a repeating bit pattern.

Jitter Spectrum
  • The jitter spectrum plot allows viewing of any periodic jitter
  • Peak annotation displays the frequencies directly on the spectrum
  • The LeCroy spectrum plot allows viewing of DDj removal for maximum comprehension
Jitter Trend
  • Time domain view of jitter shows transient jitter events often missed by viewing can be missed by viewing the histogram alone
  • The jitter trend clearly shows any non-stationary jitter seems implied by the preceding jitter trend behavior
Histogram & Bathtub
  • Measured jitter histogram clearly displays unusual jitter distributions like ­bi-modal or non-Gaussian tails. The raw data view shows possibly lost jitter ­behavior just by viewing the jitter ­decomposition
  • This unprocessed display gives a high degree of confidence in the accuracy of the jitter decomposition and bathtub curve
Cable De-embedding

Even expensive, high-performance cabling can have an adverse effect on measurements and decrease ­margin from a design. Cable losses and slow rise times can lead to intersymbol interference (ISI). The cable de-embedding feature ­removes these adverse effects providing more accurate measurements.

]]>
Teledyne LeCroy WaveMaster 816Zi http://oscilloscopes.solutions/product/teledyne-lecroy-wavemaster-816zi/ Tue, 07 Feb 2017 18:22:06 +0000 http://oscilloscopes.solutions/product/teledyne-lecroy-wavemaster-816zi/ 16 GHz, 40 GS/s, 4ch, 10 Mpts/Ch DSO with 15.3" WXGA Color Display. 50 ohm and 1 Mohm Input

Innovative, Superior, Upgradeable

LeCroy has broken bandwidth barriers by combining custom designed SiGe high-speed components with 5th generation Digital Bandwidth Interleave (DBI) technology to achieve unprecedented real-time oscilloscope performance: 30 GHz, 80 GS/s, and 512 Mpts/Ch Analysis Memory.

Most Advanced Oscilloscope Platform

X-Stream II architecture provides 10–100x faster processing of long records, true 512 Mpts analysis memory, and instantaneous instrument responsiveness. When off-line data analysis is preferred, the LeCroy Serial Interface Bus (LSIB) provides up to 325 MB/s data transfer speeds. A 15.3" WXGA touchscreen display provides 50% more viewing area compared to other oscilloscopes in this class. Both 50 Ω and 1 MΩ inputs are standard on all oscilloscopes, as is support for all LeCroy probes (including passive probes) without the need for easy to lose external adapters or expensive power supplies.

Eye Doctor™ II Advanced Signal Integrity Tools Add Measurement Precision
  • Test Fixture and Cable De-embedding
  • Emphasis Emulation
  • Serial Data Channel Emulation
  • Receiver Equalization

Add precision to signal integrity measurements by allowing the subtraction of fixture effects, and the emulation of emphasis, serial data channels, and receiver DFE, FFE, and CTLE equalization effects while at the same time maintaining fast oscilloscope processing speed on unlimited record lengths. Re-capture design margin, better understand actual circuit performance, and perform compliance testing on emerging high-speed standards, such as PCIe Gen3, USB 3.0, SAS/SATA 6 Gb/s, that require emulation to ensure high field reliability and interoperability.

Superior Serial Data Analysis

SDA II Serial Data Analysis Software provides the highest confidence for serial data testing. Eye diagram analysis provides 100x faster capture of unit intervals (UI) in the eye diagram, and is enhanced with superior eye diagram analysis tools, such as lines of constant bit error rate (IsoBER ) and mask violation locators. Superior jitter decomposition methodologies and analysis tools provides more ability to understand problem behaviors in serial data systems. X-Stream II architecture leverages the superior tools through 10–100x faster processing and complete analysis processing of full record lengths, providing more insight faster.

5th Generation Digital Bandwidth Interleave (DBI)

As memory and sample rate can be interleaved, so can bandwidth. Using high- performance microwave and RF technologies, and high-speed processors and digital signal processing (DSP), LeCroy intelligently operates high-speed analog components comfortably within their rated bandwidth range while providing twice the four channel bandwidth on two channels. This approach offers better signal fidelity compared to “stretching” of components beyond their rated bandwidth. Best Investment Protection

From the perspective of bandwidth, sample rate, processing speed, responsiveness, display size, and range of capability, the WaveMaster 8 Zi platform is clearly superior and will remain so for many years to come. With the widest bandwidth upgrade range, an engineer who is working on 2nd generation technologies today can confidently know that WaveMaster 8 Zi will support 3rd or 4th generation technology needs several years from now.

X-Stream II Architecture
Optimized for Fast Throughput

X-Stream II architecture enables high throughput of data—even when the oscilloscope is performing multiple 100 Mpts (or larger) waveforms. X-Stream II uses variable waveform segment lengths to enable all processing intensive calculations to take place in fast CPU cache memory, thus improving calculation speed and efficiency. The result—10–100x faster processing compared to other oscilloscopes.

Optimized for Long Memory

X-Stream II essentially has no analysis memory length restrictions, regardless of analysis type, since the variable waveform segment length can always be limited to a size that can fit in CPU cache memory. Other oscilloscopes with conventional architectures cannot make this claim, and often have limitations on analysis memory of 5–20% the length of their acquisition memory under the best conditions.

Optimized for Responsiveness

By dynamically allocating buffers to maximize memory availability, the WaveMaster 8 Zi Series embodies the fastest front panel responsiveness. A built-in processing abort makes front panel control changes instant by stopping the current process and allowing new waveforms to be positioned or zoomed—all without a lengthy recalculation. Meanwhile, waveform previewing shows interim calculation results.

Freedom from Probing Limitations

WaveMaster 8 Zi excels in the way it offers general purpose utility never before seen in oscilloscopes from 4 to 30 GHz. All WaveMaster 8 Zi oscilloscopes contain selectable 50 Ω and 1 MΩ input capability and can be used with any LeCroy probe—passive or active—without requiring external adapters or power supplies. Use the two inputs per channel as a built-in switch matrix.

Complete System Debug

Understanding the relationships between different signals is vital to fast debug. Only WaveMaster 8 Zi combines the best of general purpose oscilloscopes (low-speed serial triggers and decoders, mixed signal capability, high impedance probing) with specialized 50 Ω inputs. This provides ability to 100% correlate high bandwidth signal activities or problems to low-speed events, such as low-speed serial data control words, power supply noise, or parallel data transmissions. Supported serial standards are 8b10b, PCIe, PCIe 2.0, SAS, SATA, XAUI, I2C, SPI CAN, LIN, UART-RS-232, and FlexRay.

More Triggers Isolate More Problems More Effectively

A full range of serial triggers (I2C, SPI, UART, RS-232, CAN, LIN, FlexRay) are available, providing capability to isolate events related to serial peripheral bus traffic. Most serial triggers contain powerful conditional DATA triggering to allow inclusion or exclusion of entire ranges of data values, which expedites understanding of how a range of serial bus traffic DATA values interact with other signals.

TriggerScan™

TriggerScan uses high-speed hardware triggering capability with persistence displays to capture only the signals of interest and provide answers up to 100x faster than other methods.

WaveScan™ Advanced Search and Analysis Finds Problems that Triggers Won’t Find

The best trigger won’t find all unusual events—a more powerful capability is sometimes needed. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search) or “scan” for an event in many acquisitions over a long period of time. Select from more than 20 search modes (frequency, rise time, runt, duty cycle, etc.), apply a search condition and begin scanning. When an event is found, WaveScan highlights the error on screen and displays a table listing the errors.

Data Transfer Speeds 25–100x Faster

LeCroy’s Serial Interface Bus (LSIB) option enables direct connection to the PCI Express® x4 high-speed data bus in the oscilloscope to enable data transfer rates up to 325 MB/s. All that is required is installation of an optional LSIB card in the oscilloscope and the corresponding host board (card) for desktop (laptop) PC in the remote computer. Data transfer is easily enabled through a supplied application program interface (API).

Application Specific Solutions

In addition to the general purpose WaveShape Analysis tools, application specific solutions are available for Serial Data Compliance, Embedded Design, Digital Design, and Automotive. These packages extend the LeCroy standard measurement and analysis capabilities and expand your oscilloscope’s utility as your needs change.

  • Digital Filter Software Package (WM8Zi-DFP2)
  • Spectrum Analyzer Analysis Package (WM8Zi-SPECTRUM)
  • Mixed Signal Oscilloscope Option (MS-250/MS-500)
  • Jitter and Timing Analysis Package (WM8Zi-JTA2)
  • Eye Doctor II – Advanced Signal Integrity Tools (WM8Zi-EYEDRII)
]]>